July 2004
5C - 11
Functions - dosing system
C.3.4 Function: switchover of the product switch
Fig. 1
1
2
•
Two motors (1) for the auto diaphragm are
installed with a lever arm (2) in the motor
console. (Fig. 1)
•
The combined trough is equipped with two
auto diaphragms and lever wire. A perma-
nent magnet is located on the lever wire.
•
A sensor board (3) including two Hall
sensors is installed in the motor housing
component. The Hall sensors react to the
permanent magnets on the lever wires of
the auto diaphragms. (Fig. 1)
•
As a result, the control system (modules B + C)
registers two different criteria for each trough
switchover operation: (Fig. 1)
1. Position of the auto diaphragm (motor
shutdown and determination of sense of
rotation)
2. Safety inquiry (VDE regulation) to check
if the combined trough is in correct
position.
•
In principle, an initialization cycle is run
each time dispenser is switched on. If the
auto diaphragm does not reach position
within the required time (e.g. due to soil-
ing), the following functional sequence is
interrupted and an error message is indi-
cated in the LCD display. (See error codes)
Sequence following activation of the motor for
the auto diaphragm.
The lever arm (2) leaves the original position.
A
The lever arm moves into the slot of the
combined trough takes along the lever wire
(6) and the permanent magnet (5) along
and leaves the Hall sensor (7).
B
The second Hall sensor (4) shuts down the
motor for the auto diaphragm. The lever
arm repositions itself beyond the lever wire
in order to repeat the procedure in case of
renewed activation.
C
The auto diaphragm has been switched
over. The lever arm exits the combined
trough.
A
B
C
4
3
6
7
5
Cafitesse 700 - Functions - Dosing system
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...