Errors cooling system
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
30**
Cooling compartment
temperature is too high
Temperature sensor
reading: temperature
above 7°C
Automatically, when
temperature drops under
2.5°C
-
-
10
30a
Cooling compartment
temperature is too high
for a longer period of
time
Temperature sensor
reading plus timer:
temperature above 7°C
for more than 12 hours
After ON/OFF/
CLEAR
switch
Dispensing of all
products
blocked after 12
hours of more
than 7°C
1. Cooling compartment
door not fully closed
or sealed
2. Air inlet filter soiled
3. Peltier cooling units
defective
4. Temperature sensor
defective
5. PCB B/C not inserted
correctly in the rack or
defective
1. Close cooling
compartment door or
replace seal
2. Clean or replace air inlet
filter
3. Replace peltier cooling
units (see chapter 5F)
4. Replace temperature
sensor (see chapter 5F)
5. Insert PCB B/C correctly
or replace PCB B/C (see
chapter 5K)
50
31**
Cooling compartment
temperature is too low
Temperature sensor
reading: temperature
below –1°C
Automatically, when
temperature rises above
2.3°C
-
-
10
31a
Cooling compartment
temperature is too low
for a longer period of
time
Temperature sensor
reading plus timer:
temperature below –1°C
for more than 3 hours
After ON/OFF/
CLEAR
switch
Dispensing of all
products is
blocked
1. Peltier cooling units
defective
2. Temperature sensor
defective
3. PCB B/C not inserted
correctly in the rack or
defective
1. Replace peltier cooling
units (see chapter 5F)
2. Replace temperature
sensor (see chapter 5F)
3. Insert PCB B/C correctly
or replace PCB B/C (see
chapter 5K)
50
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...