16*
Normal water level
sensor defective
14
Illogical sensor reading
(e.g. low and high level
sensors detect water, but
normal level sensor does
not)
Automatically, when
there is a logical sensor
reading (e.g. low, normal
and high level sensors
detect water)
Only when 16 is
solved, 14 can
get active
1. Normal level sensor
defective
2. Wiring incorrect or
sensor connections
defective
3. PCB A not inserted
correctly in the rack or
defective
1. Replace normal level
sensor
2. Check wiring or replace
sensor connections (see
chapter 5K)
3. Insert PCB A correctly or
replace it (see chapter
5K)
111
17*
Obsolete
-
-
-
-
-
-
18*
Leaking outlet valve
(severe leak)
Software calculation:
inlet valve opens after a
certain time without
dispensing
•
After ON/OFF/
CLEAR switch OR
•
when the flush
program has been
executed OR
•
when a drink is
dispensed
After each of
these reset
conditions the
timer restarts
1. Water supply tap not
open or blocked
2. Water filter clogged or
defective
3. Water pressure too
low
4. Inlet valve defective
5. Hoses clogged or
defective
1. Open or clean tap
2. Clean or replace water
filter
3. Check water pressure
(see chapter 2)
4. Replace inlet valve (see
chapter 5A)
5. Clean or replace hoses
101
19*
Refilling boiler takes too
long
(17)
Software calculation:
counts time - 60 sec. to
fill the boiler until normal
level sensor
After ON/OFF/CLEAR
switch in OPERATOR or
SERVICE mode, the
refilling starts again
Operator can
reset error
1. Water supply tap not
open or blocked
2. Water filter clogged or
defective
3. Water pressure too
low
4. Inlet valve defective
5. Hoses clogged or
defective
1. Open or clean tap
2. Clean or replace water
filter
3. Check water pressure
(see chapter 2)
4. Replace inlet valve (see
chapter 5A)
5. Clean or replace hoses
100
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...