July 2004
5K - 6
Functions - Power supply unit
and control system
xxxxxxxxx xxxxxxx
xxxxxx xxxxxxxxxx
•
Disconnect the dispenser from the power
supply system and close the water tap.
•
Remove the drip tray (1) and the cup
carrier (2). (Fig. 2)
•
Open the right dispenser door (3) and
remove the combined trough. (Fig. 1)
•
If necessary, remove the cup carrier (4).
(Fig. 1) (See chapter D.2.2)
•
Remove the splash panel (5). (Fig. 1) (See
chapter D.2.2)
•
Pull off the following cable harnesses from
the power supply unit (Fig. 2, 4 and 5):
-
3-pin to the switched mode power
supply unit (6)
-
9-pin to the boiler (7)
-
8-pin to the module A board (8)
•
Pull out the power supply unit (9) towards
the front and then turn it upside down.
(Fig. 2)
K.2.5 Disassembly of the power supply unit and the mains cable
Fig. 1
4
5
3
2
1
Fig. 2
9
6 7 8
Cafitesse 700 - Functions - power supply and control system
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...