*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 19
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
83*
I/O module P is not
responding
Software operating
system
After ON/OFF/
CLEAR
switch in Service mode,
if initialization has
indicated a successful
communication with the
I/O module.
A communication check
is carried out every 30
seconds.
A communi-
cation check is
carried out by
the software
every 30 sec.
After ON/OFF/
CLEAR wait 30
sec. and check,
if the error is
active.
1. Software setting:
PAYMENT SYSTEM
TYPE=PAYMENT and
module P is not
installed
2. Software setting:
COLD WATER
VALVE selected for
middle BIB and
module P is not
installed
3. Wiring incorrect or
connenctions
defective
4. PCB P incorrectly
inserted in rack
5. PCB P defective
6. Left fuse on switch
mode power pack
defective
1. Correct software setting
to NO PAYMENT
2. Correct software setting:
deselect COLD WATER
VALVE for middle BIB
3. Check wiring or replace
connections (see
chapter 5K)
4. Insert PCB P correctly in
rack
5. Replace PCB P (see
chapter 5K)
6. Replace left fuse on
switch mode power pack
220
84**
Not displayed in
Cafitesse 700
85**
One BIB is empty
Software: one of the
installed BIBs are empty
Automatically when the
underlying error (40-42)
has been cleared
Only shown in
user interface
without error
number
See errors 40-42See errors 40-42
86**
Two BIBs are empty
85
Software: two of the
installed BIBs are empty
Automatically when one
of the underlying errors
(40-42) has been cleared
Only shown in
user interface
without error
number
See errors 40-42See errors 40-42
87**
Not displayed in
Cafitesse 700
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...