July 2004
Installation /
Putting into Operation
2 - 16
E1
R, S, T
∆
—
5.8 kW
—
—
3x20 A
E2
R
—
—
2.0 kW
—
10 A
—
E3
S
—
—
2.7 kW
—
on request
13 A
—
E4
T
2.2 kW
—
3 kW
—
15 A
16 A
E5
R, S, T
—
—
—
7.6 kW
3x16 A
Adjustment of the heating capacity with the rotary switch (service tool)
E
HEATING POWER MAINS FUSE MAINS VOLTAGE
Overview wiring version: EUROPE
Standard delivery: power supply cable with safety plug acc. to German/French standard,
switch position: E4 (for 230 V a 16 A fuse is necessary!)
=
=
1
6
1
2
3
5
4
1 5,8 kW
20 A
3x200 V
∆
2 2,0 kW
10 A
230 V
3 2,7 kW
13 A
230 V
4 2,2/3,0 kW 15/16 A
200/230 V
5 7,6 kW
3x16 A
3x400 V
6 -
-
-
E
HEATING POWER MAINS FUSE MAINS VOLTAGE
WIRING: EUROPE
•
white heating element (1):
R = 24.2 Ohm
±
5%
•
blue heating element (2):
S = 17.9 Ohm
±
5%
•
red heating element (3):
T = 16.1 Ohm
±
5%
Switch
position
Heating
elements
configuration
Heating capacity (kW)/mains fuse (A)
for mains voltage (V)
Required power cable/
adapter
200 V
3N 200 V
230 V
3N 400 V
Cafitesse 700 - Installation / Puttting into Operation
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...