*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 11
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
43*
Left B2 current is out of
spec
46
B2 driver circuit:
the B2 current is out of
specification
After ON/OFF/
CLEAR
switch
Locking error:
remains active
after it has
occured.
Only the drink
delivery of
products with
the B2 block
enabled is
blocked
1. Short circuit or circuit
disconnected
2. Wiring incorrect or
connections defective
3. B2 coil defective
4. PCB B not inserted
correctly in the rack or
defective
1. Repair or connect circuit
2. Check wiring or replace
connections (see
chapter 5K)
3. Replace B2 coil (see
chapter 5C)
4. Insert PCB B correctly or
replace it (see chapter
5K)
100
44*
Middle B2 current is out
of spec
47
B2 driver circuit:
The B2 current is out of
specification
After ON/OFF/
CLEAR
switch
Locking error:
remains active
after it has
occured.
Only the drink
delivery of
products with
the B2 block
enabled is
blocked
1. Short circuit or circuit
disconnected
2. Wiring incorrect or
connections defective
3. B2 coil defective
4. PCB C not inserted
correctly in the rack or
defective
1. Repair or connect circuit
2. Check wiring or replace
connections (see
chapter 5K)
3. Replace B2 coil (see
chapter 5C)
4. Insert PCB C correctly
or replace it (see
chapter 5K)
100
45*
Right B2 current is out of
spec
48
B2 driver circuit:
The B2 current is out of
specification
After ON/OFF/
CLEAR
switch
Locking error:
remains active
after it has
occured.
Only the drink
delivery of
products with
the B2 block
enabled is
blocked
1. Short circuit or circuit
disconnected
2. Wiring incorrect or
connections defective
3. B2 coil defective
4. PCB C not inserted
correctly in the rack or
defective
1. Repair or connect circuit
2. Check wiring or replace
connections (see
chapter 5K)
3. Replace B2 coil (see
chapter 5C)
4. Insert PCB C correctly
or replace it (see
chapter 5K)
100
46*
Bad dosing left B2
(<number>)
B2 driver circuit
Per dispense cycle one
error is generated with x
number of occurrences.
No reset required
Bad dosing is
recorded in the
error log only
1. Condition of the
ingredients (e.g.
sedimented or frozen)
2. Positioning of the B2
dosing unit in the coil
is not correct
1. Check condition of
ingredients, replace
product pack if required.
2. Check position of the
dosing unit
10
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...