July 2004
4 - 12
4.3 Service interface
Using the service interface of the Cafitesse 700 dis-
penser, the service technician makes the necessary
settings for running the dispenser. He configures the
operator interface, runs different tests, makes the
dispenser-specific settings, etc.
4.3.1 Entering the service mode
To enter the service mode, press the dispenser stop
button and hold the service tag at the same time in
front of the RFID (radio frequency identification) an-
tenna area. (See fig. 3 on page 4).
The start menu of the service interface is opened. It
indicates
• the software version
• the current weekday and time
• the active errors
(Fig. 22)
The active errors are listed with their respective error
numbers and a short description.
To get more information about the displayed errors,
select an active error using the scroll bar and press
MORE INFO. A short explanation about this error and
possible reasons for it are displayed. (For detailed
information about all possible errors, please refer to
chapter 3).
If possible, remedy the indicated errors.
A press on the TEST soft key links you directly to the
test menu (see section 4.3.3.2 on page 14). Here, you
can check the correct functioning of the relevant
dispenser features when remedying the errors.
If there are no active errors, the MORE INFO
and TEST soft keys are not displayed.
Press the CONTINUE soft key to open the main
service menu.
Fig. 22
SERVICE MODE (v 1.10) Wed 13:03 am
Active errors:
30: Cooling box temperature too high
MORE INFO
TEST
CONTINUE
Cafitesse 700 - Programming
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...