*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 6
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
23*
Water temperature too
low (drink quality)
Temperature sensor
reading below or equal
82°C
Automatically when
temperature has reached
T
set
Drink delivery is
blocked until
error is reset.
This can be
disabled
Not enough heating
capacity
1. Use internal elbows
2. Increase heating
capacity (3-phase
connector or pre-heater)
100
24**
Water temperature too
low (hygiene block)
Temperature sensor
reading below or equal
60°C
Automatically when
temperature has reached
T
set
Dispensing is
blocked, this
cannot be
disabled
-
-
105
25*
Water temperature
sensor defective
22, 23
24
Temperature sensor
reading (measured
temperature below
0°C (32°F) (>16400
Ω
) or
above
107°C (115°F) (<280
Ω
))
Automatically when
temperature reading is
within limits
1. Temperature sensor
defective
2. Incorrect wiring or
connections defective
3. PCB A not inserted
correctly in the rack or
defective
1. Replace temperature
sensor (see chapter 5A)
2. Check wiring or replace
connections (see
chapter 5K)
3. Insert PCB A correctly or
replace it (see chapter
5K)
120
26*
Boiler bottom is scaled
up
Software calculation
After
ON/OFF
/CLEAR of
the dispenser
This is a
warning –
delivery is not
blocked
Boiler is calcified
Decalcify boiler
10
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...