July 2004
5K - 10
Functions - Power supply unit
and control system
K.3.2 Function: switched mode power supply unit including fuse board
•
The switched mode power supply unit (1) is
supplied with alternating voltage which can
be adjusted using the change over switch
on the power supply console. (Fig. 1) (See
chapter 2)
•
The switched mode power supply unit
supplies the entire electronics system with
24 V of stabilized direct voltage.
•
The fuses (Fig. 1) protect the 24 V voltage
supply for the various modules:
(2) –
A-module
User interface
P-module
(3) –
B-module
C-module
(4) –
C-module
•
The green LEDs (5) indicate whether the
respective 24 V circuit is being supplied
with power. (Fig. 1)
•
The power supply is equipped with a
cooling fan, which is switched on automati-
cally when the temperature inside the
power supply unit is too high.
Fig. 1
1
2
5
3
4
N
L
Module
24V DC
GND
IN
OUT
Cafitesse 700 - Functions - power supply and control system
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...