July 2004
4 - 14
When an error is cleared, the date and time of clear-
ance are indicated in the Error cleared column. Still
active errors are indicated by a hyphen ("–") in this
column.
The so-called "bad dosing errors" are only
logged once (one line). The number of occur-
rences is indicated in brackets.
Scrolling through the error list displays a short descrip-
tion for each selected error.
Remedy each error. Some errors, however, are reme-
died automatically, for example, when the boiler is
refilled by the operator, or when the temperature is low
and increases again until exceeding the low tempera-
ture limit value.
4.3.3.2
TEST
Press the TEST soft key in the main service menu.
The test menu is opened. (Fig. 25)
The test menu allows you to test the correct function-
ing of the different dispenser functions.
Fig. 24 shows the structure and the different
submenus of the test menu. The submenus are named
as follows:
• BOILER TEMPERATURE
• BOILER WATER LEVEL
• OUTLET VALVES (HOT WATER)
• OUTLET VALVES (COLD WATER)
• DOSING
• MIXERS
• TROUGH
• COOLING TEMPERATURE
• BUTTONS
• TOUCH SCREEN
• RFID
• LCD
• BACK LIGHT
• SOUNDS
• ELECTRONICS
Depending on the dispenser version, fewer
menu items can be displayed on your dis-
penser than listed here. This chapter de-
scribes all possible submenus of the test
menu.
Fig. 25
TEST: please select a sub menu
BOILER TMP
BOILER LVL
OUTLET VLV
COLD WATER
DOSING
MIXERS
TROUGH
COOLNG TMP
BUTTONS
TOUCH SCRN
RFID
LCD
BACK LIGHT
SOUNDS
ELECTRONCS
Cafitesse 700 - Programming
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...