*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 5
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
20*
First boiler flling takes
too long
Software calculation
during initial filling (after
startup or
ON
/OFF/CLEAR switch):
counts time for an extra
long interval (150 sec. to
fill boiler until normal
level sensor)
After ON/OFF/CLEAR
switch in OPERATOR or
SERVICE mode, the
refilling starts again.
Operator resets
error
1. Water supply tap not
open or blocked
2. Water filter clogged or
defective
3. Water pressure too
low
4. Inlet valve defective
5. Hoses clogged or
defective
1. Open or clean tap
2. Clean or replace water
filter
3. Check water pressure
(see chapter 2)
4. Replace inlet valve (see
chapter 5A)
5. Clean or replace hoses
100
21*
Boiler water heating is
defective
Software calculation:
1. Expected temperature
rise of 5K in the first
15 min. not achieved
2. Heating system
staying on for more
than 45 min.
After ON/OFF/
CLEAR
switch in SERVICE
mode
May occur after
ERR 10 and
ERR 11
1. Heating elements or
relays defective
2. Wiring incorrect or
connections defective
3. Temperature sensor
defective
4. PCB A not inserted
correctly in the rack or
defective
1. Replace heating
elements or relays (see
chapter 5A)
2. Check wiring or replace
connections (see
chapter 5K)
3. Replace temperature
sensor (see chapter 5A)
4. Insert PCB A correctly or
replace PCB it (see
chapter 5K)
115
22*
Boiler water temperature
too high
Temperature sensor
reading:
measured temperature >
T
set
+7K OR temperature
> 107°C (217°F)
After ON/OFF/
CLEAR
switch in SERVICE
mode AND water
temperature in boiler
within normal range
After changing
T
set
in the
SETTINGS
menu, this error
is ignored for 30
min.
1. Heating elements or
relays defective
2. Temperature sensor
defective
3. Wiring incorrect or
connections defective
4. PCB A not inserted
correctly in the rack or
defective
1. Replace heating
elements or relays (see
chapter 5A)
2. Replace temperature
sensor (see chapter 5A)
3. Check wiring or replace
connections (see
chapter 5K)
4. Insert PCB A correctly or
replace it (see chapter
5K)
100
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...