July 2004
4 - 25
MIXER TEST
Press the MIXER TEST soft key in the settings menu.
The mixer test setting menu is opened. (Fig. 50)
This menu allows you to determine if the mixer test
should be carried out with or without the trough being
in place. The default setting is NO.
To change the setting, press the NO or YES key.
FLUSHING
Press the FLUSHING soft key in the settings menu.
The flushing setting menu is opened. (Fig. 51)
Here, you can set the hammer pulses during flushing
for the following valves:
• inlet valve
• hot water valve
• cold water valve
Touch the entry to be set or use the scroll bar to
switch between the settings. To change the setting,
use the DECREASE and INCREASE soft keys.
COMMUNICATION PORT
Press the COMM. PORT soft key in the settings menu.
The communication port setting menu is opened.
(Fig. 52)
This menu allows you to make settings for exchanging
data with external devices. You can make settings for
the
• communication interface
• communication protocol
• communication format
Touch the entry to be set or use the scroll bar to
switch between the settings. To define the entry, use
the PREVIOUS and NEXT soft keys and select a
predefined entry.
Fig. 52
PREVIOUS
NEXT
Communication interface
: RS232
Communication protocol
: Console
Communication format
: Text
SETTINGS: COMMUNICATION PORT
Fig. 50
NO
YES
Allow the mixer test without
the trough in place:
SETTINGS: MIXER TEST
NO
DECREASE
INCREASE
Inlet valve hammer pulses
: 6
Hot water valve hammer pulses
: 14
Cold water valve hammer pulses : 5
SETTINGS: FLUSHING
Fig. 51
Cafitesse 700 - Programming
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...