Defaults
No lossless queues are configured.
Command
Modes
INTERFACE
Command
History
Version 9.3(0.0)
Introduced on the MXL 10/40GbE Switch with the FC Flex IO
module.
Usage
Information
The maximum number of lossless queues globally supported on the switch is two.
• The following lists the dot1p priority-queue assignments.
dot1p Value in the
Incoming Frame
Description heading
0
0
1
0
2
0
3
1
4
2
5
3
6
3
7
3
pfc priority
Configure the CoS traffic to be stopped for the specified delay.
Syntax
pfc priority
priority-range
To delete the pfc priority configuration, use the
no pfc priority
command.
Parameters
priority-range
Enter the 802.1p values of the frames to be paused. Separate
the priority values with a comma; specify a priority range
with a dash; for example, pfc priority 1,3,5-7. The range is
from 0 to 7.
Defaults
none
Command
Modes
DCB INPUT POLICY
Command
History
Version 9.3(0.0)
Introduced on the MXL 10/40GbE Switch with the FC Flex IO
module.
1398
FC Flex IO Modules