454
ACU-RITE Technical Manual MILLPWR
G2
MP_maximal
Maximum value for override
Format:
Numeric value
Input:
0 to 200 [%]
Default:
150
MP_source
Source for override values
Format:
String
Input:
Key name for override device from CfgPlcOverrideDev
The percentage adjusted with the feed rate override is entered by the NC in
NN_ChnFeedOverrideInput
and
PP_ChnFeedOverride.
You can change the percentage through the PLC:
Enter the desired percentage in PP_ChnFeedOverride. The NC immediately
uses the new value.
Note
The feed rate override also applies to rapid traverse if the rapid traverse
override is not active.
PLC operand
Set
NN_ChnFeedOverrideInput
Feed rate override entered [%]
D
PP_ChnFeedOverride.
Feed rate override entered by PLC [%]
D