4.7 Overview of the Machine Parameters
243
compInsertCircleThol-
dAngle
Compensation cutoff angle. Minimizes wasted tra-
vel on acute angle. Time is wasted by "cutting air"
until the compensated point is reached. To save
time, the CNC creates an arc around the end of the
point on the work.
Unit of measure : degrees
Minimum value : 1
Maximum value : 90
Initial value : 15
Decimal places : 9
RUN / LEVEL3
compLookAheadLen
Define the number of blocks the CNC can "look
ahead" while in tool compensation for the purpose
of tool path correction.
Unit of measure : blocks
Minimum value : 0
Maximum value : 100
Initial value : 1
Decimal places : 0
RUN / LEVEL3
workUnits
Define the default working units for the system.
Select either Metric or Inch. This parameter sets
the default units (mm/inch) at startup, but can be
overriden by the program.
RUN / LEVEL3
workValues
Define the default axis values dimensioning pat-
tern. Select either Absolute or Incremental. This is
the default to activate on startup, but can be overri-
den by the program. Determines how axis values
for arcs, lines, and other moves are measured.
Absolute makes every move in reference to an
Absolute Zero position (Program Zero or Part Zero).
Incremental makes each move in reference to the
last programmed endpoint.
RUN / LEVEL3
circleCenters
Programmed Circle Center Coordinates. Select eit-
her Absolute, Incremental, or Modal. In Absolute,
the CNC interprets programmed circle center coor-
dinates as Absolute values. In Incremental, the
CNC interprets programmed circle center coordi-
nates as Incremental values. In Modal, the circle
center coordinates are interpretered based on the
currently active Absolute or Incremental mode.
RUN / LEVEL3
linearDryRunFeedrate
Linear axis dry run feedrate. When a program is run
in Dry Run Mode, the machine's linear axes (X, Y,
and optionally Z) move through the program wit-
hout cutting into the work. The movement is done
at this specified feedrate.
Unit of measure : mm / min
Minimum value : 240
Maximum value : 5100
Initial value : 2032
Decimal places : 9
RUN / LEVEL3
MP CfgUserSetup
Function and input
Reaction/Access
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......