424
ACU-RITE Technical Manual MILLPWR
G2
For further details regarding the error, such as date, time, event class, line of
the NC program, control program reporting the error, etc., proceed as follows
(see figure):
Press the
DETAILS
key.
Deleting errors
To delete an individual error:
Position the cursor on the entry to be deleted.
Press the
DELETE
key.
To delete all errors contained in the error window:
Press the
DELETE ALL
key.
Information provided by the
error message:
Error number: Assigned by HEIDENHAIN or the machine tool builder
Error class: Defines the control’s reaction to this error (see table)
Error text: Describes the error (in one or more lines) If the error occurs while
an NC program is being run, the line of the NC program will also be indi-
cated.