3.7 Touch Probe Systems
49
3.7.1 Triggering Touch Probe for Workpiece Measurement
Touch probe con-
nection
Pin layout for TS 220:
Pin layout for TS 440, TS 640 with SE 640:
Note
The interface complies with the requirements of EN 50 178 for “low
voltage electrical separation.”
MILLPWR
G2
Adapter cable 274 543-xx
TS 220
Female
Assignment
Male
Color
Pin
Pin
Color
1
0 V (internal shield)
1
2
Do not assign
2
3
Ready
3
PK
4
4
4
Start
4
5
+15 V ± 10% (U
P
), max. 100 mA
5
GY
3
3
6
+5 V ± 5% (U
P
), max. 100 mA
6
BN/GN
2
2
BN
7
Battery warning
7
GY
8
0 V (U
N
)
8
WH/GN
1
1
WH
9
Trigger signal
9
GN
5
5
GN
10
Trigger signal
a
10
YL
6
6
YL
11 to 15
Do not assign
11 to 15
Hsg.
External shield
Hsg.
External
shield
Hsg.
a. Stylus at rest means logic level HIGH.
MILLPWR
G2
Adapter cable 310 197-xx
SE 640
TS 440,
TS 640
Female
Assignment
Male
Color
Female
Male Color
1
0 V (internal shield)
1
WH/BN
7
2
Do not assign
3
Ready
3
GY
5
5
GY
4
Start
4
YL
3
3
5
+15 V ± 10% (U
P
), max. 100 mA 5
BN
2
2
BN
6
+5 V ± 5% (U
P
), max. 100 mA
7
Battery warning
7
BL
6
6
BL
8
0 V (U
N
)
8
WH
1
1
WH
9
Trigger signal
10
Trigger signal
a
10
GN
4
4
GN
11 to 15
Do not assign
Hsg.
External shield
Hsg.
External
shield
Hsg.
Hsg.
a. Stylus at rest means logic level HIGH.
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......