Modul 9276 Write operand contents into the log
The module writes the contents of PLC operands into the error log file. The
entry can be given a special identifier for fast finding or later editing.
A buffer of approx. 210 bytes is available for the data to be written (including
the entry identification).
The operands M/I/O/C/T are stored in binary format (e. g.110101), the oper-
ands B/W/D in hexadecimal format.
Call:
PS
b/w/d/k
<>Identifier operand name>
0: M (marker)
1: I (input)
2: O (output)
3: C (counter)
4: T (timer)
5: B (byte)
6: W (word)
7: D (double word)
PS
b/w/d/K
<>Address of the first operand>
PS
b/w/d/K
<>Number of operands>
PS
b/w/d/K/S
<>Log identifier>
–1: No entry
PS
b/w/d/K
<>Priority>
0: Information
1: Warning
2: Error
CM
9276
Error code:
Marker
Value Meaning
NN_GenApiModule
Error
0
Entry was written
1
Error code in NN_GenApiModuleErrorCode
NN_GenApiModule
ErrorCode
1
Invalid priority
2
Invalid identifier for operand name
3
Invalid first operand address
4
Sum of first operand address and number of
operands invalid
5
Address is not a word/double-word address
12
No string end identifier
20
Module was not called in a spawn job or submit
job
36
Entry in the log was shortened to 210
characters
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......