ACU-RITE Technical Manual MILLPWR
G2
Trigger conditions:
Specify the trigger conditions in the following input fields:
Trigger:
Set the trigger condition.
•
Single shot:
After pressing the soft key, the next 3000 events are stored.
•
Free run:
The recording is started and ended by soft key. If you press the
Stop
soft key, the last 3000 events (at most) are stored.
•
Channel 1
to
6:
Recording begins when the trigger condition of the
selected channel is fulfilled.
•
Channel 1 + L
to
channel 6 + L:
Recording begins when the trigger con-
dition of the channel selected here as well as the trigger conditions of the
digital signals (trigger condition “logic”) are fulfilled. The trigger conditions
are AND-gated.
•
Logic:
Recording begins when the trigger condition of the digital signals
is fulfilled (trigger condition “logic”).
Edge:
Set when triggering is to occur:
•
+
: Trigger at rising edge
•
–
: Trigger at falling edge
Trigger threshold:
Enter the trigger threshold (you will find the appropriate
units in the signals table on Seite 408).
Pre-Trigger:
Select a value from the selection box.
Recording begins at a time preceding the trigger time point by the value
entered here
The
Output
and
Feed rate F
fields are reserved.
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......