226
ACU-RITE Technical Manual MILLPWR
G2
refSwitchActive
400404
Active level of the trip dog for reference end
position
Format:
Selection menu
Input:
high
:
Reference end position trip dog active when
PP_AxReferenceEndPosition = 1
low
:
Reference end position trip dog active when
PP_AxReferenceEndPosition = 0
Default:
high
RUN
LEVEL3
externRefPulse
400413
(optional parameter)
Referencing with external reference signal
Format:
Selection menu
Input:
Off
:
The reference signal of the connected motor
encoder or the position encoder is used.
spindleRef (X30)
:
On systems with HSCI, the reference signal at -
SP.REF+ and -SP.REF- of the external PL is eva-
luated; on systems with MC 320 or MC 42x the
reference signal at input X30 is evaluated.
Default:
Off
RUN
LEVEL3
597 110-04
endatDiff
400405
Permissible difference of EnDat encoders
during switch-on
Format:
Numeric value
Input:
–100 000.0 to +100 000.0 [mm]
Default:
0.0 [mm]
RUN
LEVEL3
refFeedLow
400406
MP1330
Low speed when finding the reference mark
Depending on
MP_refType
, this low speed is
used for finding the reference mark.
Format:
Numeric value
Input:
0.0 to 36 000 000.0 [mm/min]
Default:
600.0 [mm/min]
RUN
LEVEL3
refFeedHigh
400407
MP1330
High speed when finding the reference mark
Depending on
MP_refType
, this high speed is
used for finding the reference mark.
Format:
Numeric value
Input:
0.0 to 36 000 000.0 [mm/min]
Default:
1200.0 [mm/min]
RUN
LEVEL3
Parameter
MP number
Function and input
Reaction/Access
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......