
5.12 Reference Marks
313
Position encoder
with distance-
coded reference
marks
Functional sequence when
MP_refType=distance coded
Reference
m
arks
Trip dog for reference
end position
Closed
Open
Traverse direction MP_refDirection
Press the external START key
Trip dog for
Reference end
position closed
Yes
No
Machine
m
oves in the
inverted traverse
direction
Yes
No
Two successive reference
m
arks traversed
Machine
m
oves in the
traverse direction
fro
m
MP_refDir
Trip dog for
ref. end position
is closed before two
successive reference
m
arks
have been traversed
Machine stops
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......