526
ACU-RITE Technical Manual MILLPWR
G2
Creating parameter
blocks, configuring
interface ports
MP_CfgSerialInterface
allows you to manage the parameter blocks for the
serial interface. Every parameter block contains the properties of a serial port.
In
MP_CfgSerialPorts,
you define which of the parameter blocks is active,
see figure on page 524. The interface settings to be defined are described
below.
MP_interfaceRs232
Keyname of the data blocks for the RS-232 interface
Format:
String
max. 18 characters
Imput:
Define the default parameter block for the serial RS-422 inter-
face here. The “Default” data block is selected by default. But
you can use any desired designation. The specified data block
must be contained in
MP_CfgSerialInterface.
The data block is
not effective if another data block was activated by the PLC.
MP_interfaceRs422
Keyname of the data blocks for the RS-422 interface
Format:
String
max. 18 characters
Imput:
Define the default parameter block for the serial RS-422 inter-
face here. The “Default” data block is selected by default. But
you can use any desired designation. The specified data block
must be contained in
MP_CfgSerialInterface.
The data block is
not effective if another data block was activated by the PLC.
MP_interfacePlc
Keynames of the data blocks for interface access by the PLC
Format:
String
[0...2]
Imput:
A string of max. 18 characters
Here you can enter a maximum of three different keynames for
interface accesses by the PLC. If no parameter block is speci-
fied, the control automatically uses the default parameter block
defined in
MP_CfgSerialInterface.
Defining the LSV2
baud rate
MP_interfaceLsv2
Keynames of the data blocks for interface access by the PLC
Format:
Selection menu
Imput:
Use the drop-down menu to define the transfer rate for the
LSV2 communication. Minimum value is 110 baud, maximum
value 115200 baud.
Default:
BAUD_57600
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......