108
ACU-RITE Technical Manual MILLPWR
G2
powerOffPort
101606
MP4041
(optional parameter)
Number of terminal in the PL module or on the
internal PL
System with HSCI interface:
Enter the number of the PLC output on the module to
be set following shut down.
System without HSCI interface:
Enter the number of the PLC output of the integrated
PL to be set following shut down.
Format:
Numerical value
Input:
0 to 31
Default:
0
NOTHING
LEVEL1
powerOffDelay
101607
MP4042
(optional parameter)
Delay time until PLC output is set
Time after shut down of the control until setting the
PLC output from
MP_powerOffPort
.
Format:
Numerical value
Input:
0 to 1000 [s]
Default:
0 [s]
NOTHING
LEVEL1
Parameter
MP number
Function and input
Behavior
Access
SW version