6.5 Control Operation in the Machining Channel
417
NC stops NC program run
:
The NC uses the following markers to inform the PLC of NC program interrup-
tion and the reason for the interruption:
NN_ChnStopExtern:
The program was interrupted because of an external
request (e.g. Stop key).
NN_ChnProgStopped:
The program was interrupted because of a program
stop (M0), the end of a block in Single block mode, etc.
NN_ChnProgStoppedAsync:
The program interruption was caused by an
error, etc.
PLC operand
Set
NN_ChnStopExtern
NC stop or cycle off
NC stop is executed by the NC.
0: NC stop not executed
1: NC stop was executed by the NC
M
NN_NN_ChnProgStopped
NC program interruption
The NC reports an asynchronous program interruption,
such as at the end of a block in Single Block mode, M0,
etc.
0: No NC program interruption
1: NC program interruption
M
NN_ChnProgStoppedAsync
Asynchronous NC program interruption
The NC reports an asynchronous program interruption,
for example because of an error, etc.
0: No asynchronous NC program interruption
1: Asynchronous NC program interruption
M
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......