6.12 Diagnosis with the Online Monitor (OLM)
493
Current status of
the channel (Act
State)
To select the
Act State
function:
Press the
Login Ipo
(or
Login SimIpo
) key.
Press the
Chnls
key.
Press the
Ipo Act State
key.
The function displays the following binary variables:
Variable
Display
rapidFeed
Rapid traverse is active for this channel
ncStopTaster
PLC request for ncStop at triggering of touch probe
override100
The override is frozen at 100%
singleStep
Single Block is active
ncStart
NC start is active
internStart
Internal NC start is active
systemCycle
A system cycle is active
ncStop
NC stop is active
programStop
Program stop (M00/M01) is active
cancel
Cancellation is active
threadCycle
Thread cycle is active
tProbeCycle
Touch probe cycle is active
tasterMonitorGeo
NC request for monitoring of touch probe
tasterMonitorPlc
PLC request for monitoring of touch probe
measure
The touch probe has triggered. (If “tasterMonitorGeo”
is set with the message “GmProbeMonitoring,”
“tasterMonitorPlc” will also be set.) Use M141 to stop
the monitoring of the touch probe temporarily (“GmPlc-
ProbeMonitoring”). This resets “tasterMonitorPlc.”
revolFProgRun
Feed rate per revolution in automatic mode is program-
med for this channel.
revolFManualMode Feed rate per revolution in manual mode is program-
med for this channel.
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......