CfgPlcMStrobe
Settings for M functions;
Output of M strobe from NC to PLC: Defines the treatment of the M function during NC program run
and the mapping to the PLC markers.
[Keys with the name or numerical code of the M strobe]
e.g. Cycle13, FN19, FN29, M3, M4, M5, M300, TouchProbe etc.
min
103901
Number of the first M Function
First M function code described in the parameter
object. The properties described in this parameter
object apply for the specified M functions.
Format:
Numerical value
Input:
0 to 9 999
Default:
0
RESET
LEVEL3
max
103902
(optional parameter)
Number of the largest M function
Code of the last (greatest) M function described in the
parameter object.
No entry: The properties of the parameter object apply
only to the M function defined in
MP_min.
Format:
Numerical value
Input:
0 to 9 999
Default:
0
RESET
LEVEL3
signal
103903
(optional parameter)
Symbolic name or number of the PLC marker that
is set when the function is decoded.
If you have not entered a value in the parameter
MP_acknowledge
, resetting this marker means an
acknowledgment of the strobe.
no entry:
The data connected with the output of the strobe is
saved without synchronization with the PLC program
and the output is immediately acknowledged.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
acknowledge
103904
(optional parameter)
Symbolic name or number of the PLC marker that
is set for acknowledging the strobe.
no entry:
The strobe is reset with the PLC marker entered in
MP_signal.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
Parameter
MP number
Function and input
Behavior
Access
SW version
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......