4.7 Overview of the Machine Parameters
167
rtsLow
106709
MP5020 bit 8
Idle state of the RTS line
Format:
Selection menu
Input:
TRUE
:
The idle state of the RTS line is logical LOW
FALSE
:
The idle state of the RTS line is logical HIGH.
Default:
FALSE
PLC/Pgm
run is locked
LEVEL2
597 110-03
noEotAfterEtx
106710
MP5020 bit 9
Behavior after reception of an ETX-control charac-
ter
Format:
Selection menu
Input:
TRUE
:
No EOT control character is sent after reception of
an ETX-control character.
FALSE
:
The control sends an EOT control character after
reception of an ETX-control character.
Default:
FALSE
PLC/Pgm
run is locked
LEVEL2
CfgServiceRequest
Settings for the Remote Diagnostics software for PCs;
Configuration of the SERVICE-REQUEST soft key. In cases of service the machine operator can trig-
ger a service request.
name
114601
(optional parameter)
Logical name of the service host
The name identifies the remote service host and can
be displayed on the user interface of the control.
Format:
String
Input:
max. 500 characters
PLC/Pgm
run is locked
LEVEL2
597 110-03
host
114602
(optional parameter)
Network address or host name of the remote ser-
vice host
Enter the network address as four decimal numbers
separated by periods (IP address in dotted-decimal
notation) or as a fully qualified host name (e.g.:
192.168.10.51
\HOME\DATA\SERVICE
Format:
String
Input:
max. 500 characters
PLC/Pgm
run is locked
LEVEL2
597 110-03
Parameter
MP number
Function and input
Behavior
Access
SW version
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......