484
ACU-RITE Technical Manual MILLPWR
G2
Actual status 1 of
the axes (Ipo Act
State 1)
To select the
Ipo Act State 1
function:
Press the
Login Ipo
(or
Login SimIpo
) key.
Press the
Axes
key.
Press the
Ipo Act State 1
key.
The function displays the status of the following binary variables (the descrip-
tions refer to the status “true”):
Variable
Display
CMD_ACTIVE
Command is active for this axis
IM_FENSTER
Following error is within the positioning tolerance
SPEED_OK
Feed rate is OK
V_OK
No acceleration active
LGR_AKTIV
Position feedback control is active
ANTRIEB_EIN
Drive is on
ANTRIEB_FREI
Drive ready for operation
MOVING
Axis is in motion (feed rate > 0)
DIRECTION
Direction of motion (true: negative direction or stand-
still)
SCHLEPP_OK
Not used
REF_OK
Axis was homed
VORSCHUB_FREI
Feed rate has been enabled (no feed stop)
NULLPULS
Reference pulse in one IPO cycle
LATCH_GUELTIG
Probe value is valid
ISTW_UEBERNOM
MEN
The current value was transferred instead of the nomi-
nal value.
SCHLEPP_AUSF_R
EQ
If position feedback control is activated, the “old” posi-
tion is approached (no compensation of following error)
REQU_POS_REAC
HED
Requested position reached.
KEINE_UEBERW
Request from PLC: No monitoring of following error or
standstill
MOVING_VNOM
Axis is in motion (nominal feed rate > 0)
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......