5.15 Integrated Oscilloscope
385
Trigger conditions
Trigger and pre-trigger conditions:
Trigger=Single shot: 3000 events beginning from the start are recorded.
Trigger=Free run: At most the last 3000 events before the
Stop
soft key is
pressed are recorded.
Trigger condition defined: The time when recording ends depends on the
setting of the pre-trigger.
• Pre-trigger=0%: 3000 events beginning from the fulfilled trigger condi-
tion are recorded.
• Pre-trigger=25% (or 50%, or 75%): 75% (or 50% or 25%) of the 3000
events beginning from the fulfilled trigger condition are recorded.
• Pre-trigger=100%: Recording is stopped. The last 3000 events before
the fulfilled trigger condition are recorded.
During recording, the selected signals are continuously displayed. You can
freeze the display of the signals with the
Display Stop
soft key. This does not
affect the recording of the signals.
The recorded data remain stored until you start recording again or activate
another graphic function.
Display Stop
A fulfilled trigger condition is indicated with a “T” in the status field at right
below the display area.
Hide/show gridlines:
Press the
Grid On
soft key.
Press the
Grid Off
soft key.
Note
If the trigger condition is fulfilled
before
the corresponding number of
events have been stored when the pre-trigger is set to 25, 50, 75 or 100%,
then correspondingly fewer events are recorded.
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......