5.13 The Control Loop
359
MP_noOffsetAdjust
Exclude axis from automatic offset adjustment
Format:
Array
Selection:
[ True ]
Axis will be excluded from offset adjustment
[ False ]
Offset of the axis is adjusted.
Default:
Optional parameter
Position loop
resolution for
analog axes
The analog voltage is subdivided 65536-fold with a 16-bit D/A converter. This
results in a smallest voltage step of 0.15 mV.
This results in the voltage DU per position error or following error sa.
The control outputs one voltage per position error.
If DU is divided by the smallest possible voltage step (0.15 mV), the result is
the number n of the possible voltage steps per position error.
U
Δ
10 000 [mV]
S
a
[µm]
--------------------------------
=