272
ACU-RITE Technical Manual MILLPWR
G2
MP_posEncoderSignal
Assignment of position-encoder input to axis
Format:
Selection menu
Selection:
[ 1Vpp ]
Input signal of encoder is 1 Vpp.
[ 11 µA ]
11 µA
Default:
1Vpp
MP_posEncoderFreq
Input frequency of position encoder inputs
Format:
Selection menu
Selection:
[ Fast ]
Input frequency
With 1 VPP:
350 kHz
With 11 µAPP:
150 kHz
[ Slow ]
Input frequency of 33 kHz
Default:
1Vpp
MP_posEncoderResistor
Terminating resistor at position encoder input
Format:
Selection menu
Selection:
[ Without ]
Without resistor
[ 120 Ohm ]
With resistor
Default:
Without