4.6 Read or Change Machine Parameters via a PLC Module
91
Module 9431 Read the numeric value of a machine parameter
Use this module to read the value of the given machine parameter from the
run-time memory.
Call only in a submit job.
Call:
PS
B/W/D/K/S<object name>
PS
B/W/D/K/S<key name>
PS
B/W/D/K/S<MP name>
PS
B/W/D/K <index>
PS
B/W/D/K <factor>
CM
9431
PL
B/W/D
<value>
PL
B/W/D
<error>
Error:
0: Module executed correctly
1: Parameter does not exist, cannot be changed, or cannot
be changed during program run
3: Fatal error (no connection to config server, etc.)
6: Not called in submit/spawn
7: Not a numeric parameter
Module 9432 Change the string value of a machine parameter
Use this module to enter a string in the machine parameter given. The value
of the machine parameter is overwritten in the run-time memory. The machine
parameter in the *.cfg file is not overwritten. The overwritten parameters are
only in effect until the next control start-up.
Call only in a submit job.
Call:
PS
B/W/D/K/S<object name>
PS
B/W/D/K/S<key name>
PS
B/W/D/K/S<MP name>
PS
B/W/D/K <index>
PS
B/W/D/K/S<new string>
CM
9432
PL
B/W/D
<error>
Error:
0: Module executed correctly
1: Parameter does not exist, cannot be changed, or cannot
be changed during program run
3: Fatal error (no connection to config server, etc.)
5: Call during program run without a strobe
6: Not called in submit/spawn
7: Parameter is not a string
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......