6.7 Keystroke Simulation
443
Modul 9182 Re-enable NC key by PLC
The module cancels the effect of Module 9181.
Call:
PS
b/w/d/k
<>Key code>
CM
9182
PL
b/w/d
<>Error status>
0: NC key disabled
–1: For error see NN_GenApiModuleErrorCode
Error code:
Modul 9183 Disable NC key groups by PLC
The module disables the specified key group. The table at the end of this chap-
ter contains the assignment of the keys to the key groups.
The key-group codes are:
0: All keys
1: ASCII
2: Keys, Page Up/Down
3: Cursor, ENT, NOENT, DEL, END, GOTO
4: Numbers, algebraic signs, decimal point, actual position capture
5: Operating modes
6: Block opening keys
Call:
PS
b/w/d/k
<>Key-group code>
CM
9183
PL
b/w/d
<>Error status>
0: Group of NC keys disabled
–1: Transferred value> maximum value
Error code:
Marker
Value Meaning
NN_GenApiModule
Error
0
Disabling was canceled
1
Error code in NN_GenApiModuleErrorCode
NN_GenApiModule
Error
1
Transferred parameter > maximum value
2
Transferred parameter invalid
Marker
Value Meaning
NN_GenApiModule
Error
0
The group of NC keys was disabled
1
Error code in NN_GenApiModuleErrorCode
NN_GenApiModule
Error
2
Transferred parameter invalid
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......