Modul 9184 Enable locked NC key groups by PLC
The module cancels the effect of Module 9183 for the given key group. The
table at the end of this chapter contains the assignment of the keys to the key
groups.
The key-group codes are:
0: All keys
1: ASCII
2: Keys, Page Up/Down
3: Cursor, ENT, NOENT, DEL, END, GOTO
4: Numbers, algebraic signs, decimal point, actual position capture
5: Operating modes
6: Block opening keys
Call:
PS
b/w/d/k
<>Key-group code>
CM
9184
PL
b/w/d
<>Error status>
0: Group of NC keys disabled
–1: Transferred value> maximum value
Error code:
Marker
Value Meaning
NN_GenApiModule
Error
0
Disabling was canceled
1
Error code in NN_GenApiModuleErrorCode
NN_GenApiModule
Error
2
Transferred parameter invalid