128
ACU-RITE Technical Manual MILLPWR
G2
split
103908
(optional parameter)
The M function is split into the specified M func-
tions
The currently active M function can be split into the
two specified M functions. You can cancel it in part by
canceling one of the specified M functions. The cur-
rently active M function is split up if part of it is can-
celed by the
MP_revoke
parameter.
Example: M13 = Spindle ON clockwise (M3) + coolant
ON (M8)
If function M13 is active and an M5 is collected during
the block scan, for example, the function M3 contai-
ned in M13 is canceled. Only function M8 remains
active. In this case, enter
3
and
8
into the parameter.
Format:
List [2] with numeric values
Input:
Numbers of M functions
RESET
LEVEL3
track
103914
(optional parameter)
Automatic update of the active M functions
Normally the PLC program has to use the Module
9088 to implement the status of the active M function.
Set this parameter to TRUE if the PLC runtime system
is to implement the status automatically.
Format:
Selection menu
Input:
TRUE
:
The status of the active M function is implemented
automatically, depending on the
MP_trackMState
parameter (CfgPlcOptions).
FALSE
:
The status of the active M function must be imple-
mented by calling Module 9088.
RESET
LEVEL3
blockEnd
103910
M function output at block end or block beginning.
Format:
Selection menu
Input:
TRUE or FALSE
TRUE
:
Function is executed at block end.
FALSE
:
Function is executed at beginning of block.
Default:
FALSE
RESET
LEVEL3
Parameter
MP number
Function and input
Behavior
Access
SW version
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......