314
ACU-RITE Technical Manual MILLPWR
G2
Position encoder
with one reference
mark
Functional sequence when
MP_refType=without Switch
Press the external START key
Trip dog for
Reference end
position closed
Yes
No
Machine
m
oves in the
inverted traverse
direction
Yes
No
Reference
m
ark is traversed
Machine
m
oves in the
traverse direction
fro
m
MP_refDir
Trip dog for
ref. end position
is closed before the
reference
m
ark
is traversed
Machine stops
Reference
m
ark
Trip dog for reference
end position
Traverse direction MP_refDirection
Closed
Open