4.7 Overview of the Machine Parameters
131
acknowledge
104003
(optional parameter)
Symbolic name or number of the PLC marker that
is set for acknowledging the strobe.
no entry:
The strobe is reset with the PLC marker entered in
MP_signal.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
spindleSpeed
104004
(optional parameter)
Symbolic name or number of the PLC word for
transmitting the spindle speed
Name of the PLC word in which the spindle speed is
transmitted to the PLC.
No input:
The spindle speed cannot be read as a numerical
value.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
badSpeed
104005
(optional parameter)
Symbolic name or number of the PLC marker for
impermissible spindle speeds
Name of the PLC marker which is set if the spindle
speed is outside the permissible range.
No entry:
The spindle speed is not monitored.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
cuttingSpeed
104018
(optional parameter)
Symbolic name or number of the PLC word for
transmitting the constant cutting speed
Name of the PLC word in which the constant cutting
speed is transmitted to the PLC.
No entry:
The constant cutting speed cannot be read as a nume-
rical value.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
gearCode
104007
(optional parameter)
Symbolic name or number of the PLC word for the
gear range
Name of the PLC word in which the gear range is
transmitted to the PLC.
No entry:
No gear range is transmitted.
Format:
String
Input:
PLC operand, max. 80 characters
RESET
LEVEL3
Parameter
MP number
Function and input
Behavior
Access
SW version
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......