266
ACU-RITE Technical Manual MILLPWR
G2
MP_posEncoderType
Position measurement by position encoder or motor encoder
Format:
Selection menu
Selection:
[ MC distance coded ]
Distance-coded position encoder
[ MC not distance coded ]
No distance-coded position encoder
[ no encoder ]
No position measurement
Default:
MC not distance coded
MP_distPerMotorTurn
Distance of one motor revolution
Format:
Numeric value
Input:
0.000 000 001 to 1000 [mm] or [°]
Default:
5 [mm] or [°]
Note
The parameter
MP_distPerMotorTurn
is not effective for analog axes.
However, you should not enter 0 for this parameter.
HEIDENHAIN recommends that you enter 1 for this parameter.