4.7 Overview of the Machine Parameters
165
protocol
106702
MP5030
Communications protocol
Format:
Selection menu
Input:
STANDARD
:
Standard data transfer. Data transferred line-by-line.
BLOCKWISE
:
Package-based data transfer, so-called ACK/NAK
protocol. Blockwise data transfer is controlled by
the control characters ACK (Acknowledge) and NAK
(Not Acknowledge).
RAW_DATA
:
Data transferred without protocol. Transfer of cha-
racters without control characters. Protocol inten-
ded for transfer of data of the PLC.
Default:
STANDARD
PLC/Pgm
run is locked
LEVEL2
dataBits
106703
MP5020 bit 0
Data bits in each transferred character
Format:
Selection menu
Input:
7 bits
:
7 data bits are transferred for each character trans-
ferred
8 bits
:
8 data bits are transferred for each character trans-
ferred.
Default:
8 bits
PLC/Pgm
run is locked
LEVEL2
parity
106704
MP5020 bit 4/5
Type of parity checking
Format:
Selection menu
Input:
NONE
:
No parity formation
EVEN
:
Even parity
ODD
:
Odd parity
Default:
NONE
PLC/Pgm
run is locked
LEVEL2
stopBits
106705
MP5020 bit 6/7
Number of stop bits
Format:
Selection menu
1 stop bit
:
1 stop bit is appended after each transferred charac-
ter.
2 stop bits
:
2 stop bits are appended after each transferred cha-
racter.
Default:
1 stop bit
PLC/Pgm
run is locked
LEVEL2
Parameter
MP number
Function and input
Behavior
Access
SW version
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......