4.7 Overview of the Machine Parameters
225
CfgReferencing
Axis parameters for the reference run;
For rotary axes and spindles, the velocity is specified in [°/min].
refType
400401
MP1350
Sequence for finding the reference mark
Format:
Selection menu
Input:
None
:
No traversing of the reference marks
If the reference run with the spindle is perfor-
med via a trip dog, this value must be set.
Switch, changing Dir
:
For linear axes with speed encoder; reference
run with NC start
Switch, no changing Dir
:
For linear axes with speed encoder; reference
run with NC start
without Switch
:
For spindle, rotary table with angle encoder;
reference run with NC start
distance coded
:
For distance-coded linear encoders; reference
run with NC start
distance coded + on the fly
:
For distance-coded linear encoders; reference
run with axis-direction keys or NC start
without on the fly
:
For spindle; reference run with M3, M4
Endat Encoder
:
For axes with EnDat encoder; reference-mark
traverse not necessary
Default:
Switch, changing Dir
RUN
LEVEL3
refPosition
400403
MP960,
MP3430
Position of the machine datum
Position is defined relative to the scale reference
point. For encoders with distance-coded refe-
rence marks, with respect to the zero reference
mark.
For EnDat encoders, with respect to the absolute
encoder datum.
Format:
Numeric value
Input:
-100 000.0 to + 100 000.0 [mm]
Default:
100.0 [mm]
RUN
LEVEL3
Parameter
MP number
Function and input
Reaction/Access
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......