228
ACU-RITE Technical Manual MILLPWR
G2
moveAfterRefFeed
400412
Feed rate for positioning after traversing the
reference mark
Format:
Numerical value
Input:
10.0 to 36 000 000.0 [mm/min]
or [°/min]
Default:
6 000.0 [mm/min] or [°/min]
RUN
LEVEL3
CfgPositionLimits
Axis-specific setting of the software limit switches;
Only one range of traverse is supported at present by the TNC 320.
swLimitSwitchPos
400501
MP910
Positive software limit switch
If positive and negative software limit switches =
0, monitoring is switched off.
Format:
Numeric value
Input:
–100 000.0 to +100 000.0 [mm]
Default:
0.0 [mm]
RUN
LEVEL3
swLimitSwitchNeg
400502
MP920
Negative software limit switch
If positive and negative software limit switches =
0, monitoring is switched off.
Format:
Numeric value
Input:
–100 000.0 to +100 000.0 [mm]
Default:
0.0 [mm]
RUN
LEVEL3
lubricationDist
400503
MP4050
Path-dependent lubrication of axis
Format:
Numeric value
Input:
0.000 to +100 000.000 [mm]
0: no output of lubrication pulse to
PLC
output
Default:
100.0 [mm]
RUN
LEVEL3
CfgControllerAuxil
General parameters for the position controller
driveOffLagMonitor
400601
Following-error monitoring with drive swit-
ched off
Format:
Selection menu
Input:
on
:
Monitoring of hanging axes is active
off
:
Monitoring of hanging axes is not active
Default:
off
RUN
LEVEL3
Parameter
MP number
Function and input
Reaction/Access
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......