534
ACU-RITE Technical Manual MILLPWR
G2
Block Check
Character (BCC)
The BCC is a block check character. The BCC is added to a transfer block to
simplify error detection. During the horizontal parity check and the cyclic block
check, block check characters are calculated and added to every transferred
data block. The appended BCC is compared with a second BCC that is calcu-
lated by the receiver. The comparison determines whether the transmission
was executed without error.
Use
MP_bccAvoidCtrlChar
to ensure that the BCC is not interpreted as a
control character.
On the control, numbers less than $20 are defined as control characters. If cal-
culation of the BCC produces a number less than $20, then a blank space is
sent in addition immediately before <ETB>. The BCC will consequently
always be greater than $20 and cannot therefore be interpreted as a control
character.
MP_bccAvoidCtrlChar
Block Check Character (BCC) is not a control character
Format:
Selection menu
Selection:
[ TRUE ]
Ensures that the check sum does not correspond to a control
character.
[ FALSE ]
Function not active
Default:
FALSE
Note
You can remove this parameter from your configuration if you do not use
blockwise data transfer.
Summary of Contents for MILLPWR G2
Page 1: ...Technical Manual ACU RITE MILLPWRG2 ...
Page 2: ......
Page 14: ...14 ACU RITE Technical Manual MILLPWRG2 ...
Page 40: ...40 ACU RITE Technical Manual MILLPWRG2 ...
Page 58: ...58 ACU RITE Technical Manual MILLPWRG2 3 10 3 USB Hub ...
Page 60: ...60 ACU RITE Technical Manual MILLPWRG2 TS 220 Adapter cable for TS 120 TS 220 ...
Page 61: ...3 10 Dimensions 61 SE 640 transmitter receiver unit ...
Page 62: ...62 ACU RITE Technical Manual MILLPWRG2 SE 540 transmitter receiver unit ...
Page 63: ...3 10 Dimensions 63 TS 440 TS 640 ...
Page 64: ...64 ACU RITE Technical Manual MILLPWRG2 ...
Page 392: ...392 ACU RITE Technical Manual MILLPWRG2 ...
Page 545: ......