6.8.3 Override Functions
Speed override
In the parameter object
CfgPlcOverrideS,
create a parameter block for each
spindle to which a spindle speed override is to apply.
MP_minimal
Minimum value for override
Format:
Numeric value
Input:
0.000 to 100.000 [%]
Default:
0
MP_maximal
Maximum value for override
Format:
Numeric value
Input:
0.000 to 200.000 [%]
Default:
150
MP_source
Source for override values
Format:
Numeric value
Input:
0.00010 to 0.10000
Default:
String of max. 16 characters
Key name for override device from CfgPlcOverrideDev
Settings in the configuration editor:
System
PLC
CfgPlcOverrideS
Key name of spindle
minimal
maximal
source