Failure to comply with the following can cause erratic operation of the control and/or unit:
•  Never install more than one main wall control per ventilation unit.

 •  Keep control low voltage wiring at least 1 foot (305 mm) away from motors, lighting balast, light dimming circuit 

and power distribution panel. Do not route control wiring alongside house power wiring.

•  Ensure the wires are securely connected.



Unplug the ventilation unit.

VC0217

VC0219



Unscrew the screw located on the

underside of the wall control.

Separate the front module from the 

mounting plate by lifting its bottom 

part.

  12V    D-    D+   Gnd



Strip the end of the cable to access 

the 4 wires (about 3"). Strip the end 
of each wire (about 1/4"). Connect the 
wires to the terminals, regardless of 
the wire color. Note which wire color 
has been chosen for each terminal.

VC0218



Install the front module on the
mounting plate. Fix both parts by 
screwing the screw on the underside 
of the wall control.

Be careful not to pinch wires when reinstalling the 
front module on the mounting plate.

CAUTION



Plug the ventilation unit in power source.

This control is compatible with all AI and N series units.

23840 rev. 03



Perform the electrical connection to the terminal connector of 
the unit, as shown below. For more details, refer to the
installation manual of the ventilation unit.

  

12V   D-  D+ Gnd

VC0232

NOTE: To avoid miswiring, refer to the notes taken at step

 

 

to match the wire color with the right terminal.

W

ALL

 

CONTROL

 

REAR

 

VIEW

NOTE: If the control is to be installed in an electric box, do 
not perform steps 3 and 4.

I

NSTALLATION

 

AND

 U

SER

 G

UIDE

 

FOR

 

VÄN

EE 

AND

 V

ENMAR

 A

DVANCED

 T

OUCHSCREEN

 C

ONTROL

READ AND SAVE THESE INSTRUCTIONS

The illustrations in this document are generic; your control appearance may be slightly different from the ones shown.

Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. 
Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting 
means to prevent power from being switched on accidentally. Always wear safety glasses and gloves while 
performing these instructions.

    WARNING

!

VC0255



Using the mounting plate, mark the 
hole opening and screw locations at 
the desired height on the wall.

VC0244A

Ø 3/16", typ. 



Cut the hole opening using the mark 
previously drawn (1/8" outside the 
mark is recommended). Drill both 
screw holes (3/16" Ø) in wall and 
insert the wall anchors (included).



Fix the mounting plate to the wall using the screws provided.

If ducts have to go through an unconditioned space (e.g.: attic), always use insulated ducts to prevent condensation 
formation inside and outside ducts, which could cause material damage and/or mold growth. Moreover, if fresh air 
to building duct and/or stale air from building duct goes/go through an unconditioned space, the unit must be set 
to operate continuously in cold conditions (below 10°C/50°F). Continuous air movement inside ducts will prevent 
condensation formation. The unit can be stopped temporarily for maintenance and/or repair purposes in such 
conditions. (Refer to section 2.2 from unit User and Installer Manual for more details.)

CAUTION

CAUTION

Reviews: