362 Technical data
Ethernet link
Installation
Into an option slot on the drive control unit
Degree of protection
IP20
Ambient conditions
The applicable ambient conditions specified for
the drive in its manuals are in effect.
Package
Cardboard. Plastic wrapping: Antistatic air bubble
sheet (PE).
Indicators
Three bicolor LEDs (HOST, MODULE,
NETWORK/NET)
Connectors
A 20-pin connector to the drive
RJ-45 connector to Ethernet (X1)
FENA-21 only: RJ-45 connector for chaining
another adapter module (X2)
Power supply
+3.3 V
±
5% max. 400 mA (supplied by the drive)
General
Complies with EMC standard EN 61800-3:2004
Printed circuit board conformal coated
Compatible devices
Ethernet Standard IEEE 802.3 and IEEE 802.3u
devices
Medium
10BASE-TX or 100Base-TX with Auto-
negotiation and Auto-MDIX (Auto-crossover)
• Wiring: CAT5/6 UTP, CAT5/6 FTP, CAT5/6
STP
• Connector: RJ-45
• Termination: Internal
• Maximum segment length: 100 m / 328 ft
Topology
Bus or star.
Max. 50 nodes allowed for FENA-21 in a daisy
chain topology.
Transfer rate
10 Mbps or 100 Mbps
Serial communication
type
Half or full duplex
Protocol
Modbus/TCP, EtherNet/IP, PROFINET IO
Summary of Contents for FENA-01
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 32: ...32 Introduction to the manual ...
Page 38: ...38 Overview of the Ethernet network and the FENA 01 11 21 module ...
Page 42: ...42 Mechanical installation ...
Page 46: ...46 Electrical installation ...
Page 48: ......
Page 94: ...94 Modbus TCP Communication profiles ...
Page 106: ...106 Modbus TCP Communication protocol ...
Page 112: ...112 Modbus TCP Diagnostics ...
Page 114: ......
Page 154: ...154 EtherNet IP Start up 3 In the Select Module window select ETHERNET MODULE ...
Page 180: ...180 EtherNet IP Communication profiles ...
Page 246: ......
Page 304: ...304 PROFINET IO Start up ...
Page 374: ...374 AppendixA PROFIdriveparametersandI MrecordsofPROFINETIO ...