EtherNet/IP – Communication protocol 199
ABB Drives profile with set speed and set
torque assembly
The ABB Drives profile with set speed and set torque assembly is
defined by ABB. The format of the output assembly is:
16
DATA IN 7 Value (Low Byte)
17
DATA IN 7 Value (High Byte)
18
DATA IN 8 Value (Low Byte)
19
DATA IN 8 Value (High Byte)
20
DATA IN 9 Value (Low Byte)
21
DATA IN 9 Value (High Byte)
22
DATA IN 10 Value (Low Byte)
23
DATA IN 10 Value (High Byte)
Instance 2 (ABB Drives profile)
Byte Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reset Ramp
in
Zero
Ramp
Hold
Ramp
Out
Zero
Inhibit
Oper-
ation
Off 3
Control
Off 2
Control
Off 1
Control
1
Ext
Ctrl
Loc
Remote
Cmd
2
Set Speed (Low Byte)
3
Set Speed (High Byte)
4
Set Torque (Low Byte)
5
Set Torque (High Byte)
Instance 151 (ABB Drives profile)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Summary of Contents for FENA-01
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 32: ...32 Introduction to the manual ...
Page 38: ...38 Overview of the Ethernet network and the FENA 01 11 21 module ...
Page 42: ...42 Mechanical installation ...
Page 46: ...46 Electrical installation ...
Page 48: ......
Page 94: ...94 Modbus TCP Communication profiles ...
Page 106: ...106 Modbus TCP Communication protocol ...
Page 112: ...112 Modbus TCP Diagnostics ...
Page 114: ......
Page 154: ...154 EtherNet IP Start up 3 In the Select Module window select ETHERNET MODULE ...
Page 180: ...180 EtherNet IP Communication profiles ...
Page 246: ......
Page 304: ...304 PROFINET IO Start up ...
Page 374: ...374 AppendixA PROFIdriveparametersandI MrecordsofPROFINETIO ...