EtherNet/IP – Communication protocol 225
Instance attributes (Instance
#1)
#
Attribute
name
Services
Description
Data
type
3
At Reference
Get
Frequency arrival
BOOL
4
NetRef
Get, Set
Requests torque or speed
reference to be local or from
the network.
0 = Set Reference not DN
Control
1 = Set Reference at DN
Control
Note that the actual status of
torque or speed reference is
reflected in attribute 29,
RefFromNet.
BOOL
6
Drive mode
Get, Set
0 = Vendor specific
UINT8
7
Speed Actual
Get
Units = See parameter
23
ODVA SPEED SCALE
.
SINT16
8
SpeedRef
Get, Set
Units = See parameter
23
ODVA SPEED SCALE
.
SINT16
11 Torque Actual Get
Units = See parameter
24
ODVA TORQUE SCALE
.
SINT16
12 TorqueRef
Get, Set
Units = See parameter
24
ODVA TORQUE SCALE
.
SINT16
18 AccelTime
Get, Set
Units = milliseconds
UINT16
19 DecelTime
Get, Set
Units = milliseconds
UINT16
22 Speed Scale
Get, Set
Speed scaling factor. See
parameter
23
ODVA SPEED
SCALE
.
UINT8
24 Torque Scale
Get, Set
Torque scaling factor. See
parameter
24
ODVA TORQUE
SCALE
.
UINT8
29 Ref From Net Get
Reflecting attribute 4
BOOL
Summary of Contents for FENA-01
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 32: ...32 Introduction to the manual ...
Page 38: ...38 Overview of the Ethernet network and the FENA 01 11 21 module ...
Page 42: ...42 Mechanical installation ...
Page 46: ...46 Electrical installation ...
Page 48: ......
Page 94: ...94 Modbus TCP Communication profiles ...
Page 106: ...106 Modbus TCP Communication protocol ...
Page 112: ...112 Modbus TCP Diagnostics ...
Page 114: ......
Page 154: ...154 EtherNet IP Start up 3 In the Select Module window select ETHERNET MODULE ...
Page 180: ...180 EtherNet IP Communication profiles ...
Page 246: ......
Page 304: ...304 PROFINET IO Start up ...
Page 374: ...374 AppendixA PROFIdriveparametersandI MrecordsofPROFINETIO ...