B337EN07.doc
Maintenance of laser
7-31
Maintenance point
Interval /
Operating
hours
Maintenance information
Generator tube
1000 h,
after 6 months
Check operating values of the generator tube
The generator tube must be replaced if the generator power
decreases or the operating values exceed the permitted deviations.
The operating values are determined while generator is being
operated. They are determined when the unit is warm (after beam
has been on for 10 minutes) in order to be able to compare the
values.
Generator IS18
Generator IS22
Generator IS36/IS44
P
BI
Õ
1000 W
P
BI
Õ
2000 W
P
BI
Õ
650 W
If the values of the exciter stage P
BI
forward power approach the
limit values listed above, then the tube is worn out and should be
replaced. The power output P
I
begins to decrease as soon as the
limit values have been reached. If the generator tube is not
replaced before de-energization of P
I
, then the power output of the
laser unit will be reduced.
Danger
The operating values are measured while the unit is in service
mode. If an operating error is made, beam emission at the
machining head may occur. To determine the operating values,
perform the following steps only:
•
Switch on the control system.
•
Use the key switch to switch on the service mode.
•
Carry out the operation steps as described in chapter 7.4
"Operation steps on the Siemens control system for
maintenance work/checking generator values"
•
Compare the respective current state with the values in the
delivery protocol.
•
Make a note of the current values.
•
Use the key switch to switch on the automatic mode.
Limit values P
BI
The forward power of the exciter stage P
BI
is particularly indicative
for the functioning of the generator tubes.
Содержание LASERCELL 1005
Страница 1: ...Operator s manual TRUMPF LASERCELL 1005...
Страница 2: ......
Страница 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Страница 6: ...0 6 Before You proceed B337EN00 DOC...
Страница 22: ...0 22 Table of Contents B337EN00 DOC...
Страница 23: ...1...
Страница 61: ...1 38 Laser processing B337EN01 DOC...
Страница 62: ...2...
Страница 107: ...3...
Страница 160: ...4...
Страница 238: ...4 78 Operation B337EN4_3 Fig 39422 Fig 39423en Cutting a large contour Cutting a medium contour...
Страница 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Страница 409: ...B337EN4_8 Operation 4 249 Fig 36626 Fig 36627 Backup starts 6 Enter file name press Enter 7 Press Y...
Страница 412: ...4 252 Operation B337EN4_8...
Страница 413: ...5...
Страница 515: ...5 102 Further service programs B337EN05 DOC...
Страница 516: ...6...
Страница 546: ...6 30 Machine maintenance B337EN06 doc 5 Maintenance of pneumatic components and filters 5 1 Instrument panel Fig 39484...
Страница 589: ...7...
Страница 628: ...8...
Страница 635: ...B337EN08 DOC Cross hairs to cut out 8 7 5 Cross hairs to cut out Cross hairs to cut out Fig 6310...
Страница 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Страница 637: ...9...
Страница 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Страница 644: ...10...