B337EN06.doc
Machine maintenance
6-37
Maintenance point no.
Interval
operating
hours
Maintenance note
Procedure
46
Beam guideway
pressure
Fig. 39488
500
Inspection
The beam guideway is permanently ventilated with flow
pressure to keep dirt particles from settling onto optical
components. The flow pressure has been set at factory via a
throttle valve to 0.4 mbar.
Machine is switched on. Measurement is carried out along
the longest beam path with the axes immobile.
1. Move axes to Z=0, Y=1500 and X=2000 (3000 or 4000).
2.
Fill the U tube manometer with measuring fluid up to the
"0" marking.
3.
Remove connection screw (1) and connect U tube
manometer.
The pressure differential "p" between the left and right co-
lumns of the U tube manometer must equal 0.4
±
0.1 mbar.
One graduation mark corresponds to 0.1 mbar.
4.
If the pressure differential is greater or lower than
0.4
±
0.1 mbar, the pressure must be reset.
U tube manometer connection
Fig. 39488
1
p
0
A
1
Connection screw for
A
U tube manometer
U tube manometer
p
pressure differential
Содержание LASERCELL 1005
Страница 1: ...Operator s manual TRUMPF LASERCELL 1005...
Страница 2: ......
Страница 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Страница 6: ...0 6 Before You proceed B337EN00 DOC...
Страница 22: ...0 22 Table of Contents B337EN00 DOC...
Страница 23: ...1...
Страница 61: ...1 38 Laser processing B337EN01 DOC...
Страница 62: ...2...
Страница 107: ...3...
Страница 160: ...4...
Страница 238: ...4 78 Operation B337EN4_3 Fig 39422 Fig 39423en Cutting a large contour Cutting a medium contour...
Страница 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Страница 409: ...B337EN4_8 Operation 4 249 Fig 36626 Fig 36627 Backup starts 6 Enter file name press Enter 7 Press Y...
Страница 412: ...4 252 Operation B337EN4_8...
Страница 413: ...5...
Страница 515: ...5 102 Further service programs B337EN05 DOC...
Страница 516: ...6...
Страница 546: ...6 30 Machine maintenance B337EN06 doc 5 Maintenance of pneumatic components and filters 5 1 Instrument panel Fig 39484...
Страница 589: ...7...
Страница 628: ...8...
Страница 635: ...B337EN08 DOC Cross hairs to cut out 8 7 5 Cross hairs to cut out Cross hairs to cut out Fig 6310...
Страница 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Страница 637: ...9...
Страница 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Страница 644: ...10...